Question No : 1
During planned maintenance of a four-node vSAN cluster, an outsourced IT contractor accidentally removed a 2.5" SSD cache disk from one of the vSAN nodes. The storage policy has been configured with FTT=1 RAID 1, and the disk management UI marked the disk group as absent.
Which remediation steps should the administrator select to ensure VMs become compliant with the storage policy as soon as possible?

正解:

Question No : 2
An administrator receives an alert for vCenter being unavailable. With vCenter running on vSAN, the administrator wants to know if any other VMs are impacted .
What command can an administrator run to determine the overall health of the vSAN objects?

正解:
Explanation:
Reference: https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/products/vsan/vmwarevirtual-san-health-check-guide-6.1.pdf

Question No : 3
A failed storage controller has two vSAN disk groups attached. The components contained on the dnves in those disk groups are marked Degraded. vSAN reports that some objects do not comply with their assigned storage policy.
How is the compliance issue resolved?

正解:

Question No : 4
A customer has lost connectivity to one of their sites In a vSAN Stretched Cluster.
When connectivity is restored, what DRS setting will ensure VMs are not migrated back before resyncs are complete?

正解:

Question No : 5
Reference the exhibit.



A university campus has a site topology illustrated in the exhibit. Adjacent connected buildings are connected with a single 40gb layer 3 network with a RTT of 0.6ms as depicted by each line. An architect wants to configure a fault domain in each building.
What would the architect need change in order to implement a fully supported vSAN Cluster?

正解:

Question No : 6
An administrator arrives at work and begins their morning checks on a four node, all-flash vSAN Cluster. They notice the vSAN datastore reached 99% capacity due to a single node failure.
How can the administrator provide temporary relief?

正解:

Question No : 7
Refer to the exhibit:



There are three hosts in a vSAN cluster. All virtual machines in the cluster are assigned a
storage policy with failures to tolerate set to 1 failure - RAID-1 (Mirroring) .
What is the result of placing a host in maintenance mode using the options shown in the image?

正解:

Question No : 8
Which step can be avoided when replacing a capacity tier device on a controller with passthrough mode and support for hot-plug?

正解:
Explanation:
Reference: https://docs.vmware.com/en/VMware-vSphere/6.5/virtual-san-66-administration-guide.pdf (31)

Question No : 9
When designing a vSAN Cluster, which three should be considered when sizing a vSAN datastore? (Choose three.)

正解:
Explanation:
Reference: https://core.vmware.com/resource/vmware-vsan-design-guide

Question No : 10
A vSAN administrator is changing the number of stripes in the vSAN policy from 1 to 2 on a 3-node vSAN Cluster .
What is a possible impact of this policy change?

正解:

Question No : 11
Where would an administrator enable deduplication and compression in a vSAN environment?

正解:

Question No : 12
Which is true of the vSAN iSCSI target service?

正解:

Question No : 13
Refer to the exhibit.



An administrator is managing a 4-node, hybrid vSAN cluster. One of the hosts in the cluster went offline.
Referencing the information displayed in the resyncing objects section of the vSAN UI, what is the current state of this cluster?

正解:
Explanation:
Reference: https://core.vmware.com/resource/vsan-2-node-guide#sec11-sub3

Question No : 14
Which storage policy can be assigned to virtual machines In a 5-node, all flash vSAN cluster, to provide the highest level of redundancy?

正解:

Question No : 15
As part of a security strategy for data, a company has elected to migrate to a new KMS system.
Existing vSAN clusters are configured for Data At Rest Encryption. Considering the scenario, which statement is true?

正解: